Home Contact Us
Industry Dynamics

Jotun’s Knutsen LNG coating selection: what the yard should record

Jotun says HPS 2.0 was selected for nine Knutsen LNG carriers. See which coating records to request at tender, yard inspection and in service.

Published on · Published by MOSINTER GROUP Editorial Team · About 4 min read
Scale model of a curved ship hull section with differently coated areas.

On 18 November 2026, Jotun announced that its Hull Performance Solutions (HPS 2.0) had been selected for nine Knutsen LNG carriers to be built at Hanwha Ocean in South Korea. Each vessel has a nominal cargo capacity of 174,000 m³. Jotun reported that steel cutting was scheduled to begin in January 2027. For a newbuilding team, this is a useful reminder to agree on evidence at two different points in the contract: coating application at the yard and hull performance after the ship enters service.

AI-generated illustration of a generic coated hull section. The model does not depict an actual ship or shipyard.

What the selection tells a buyer

Jotun says the evaluation emphasised antifouling technology and long-term coating performance. Its public announcement gives the selected solution and the programme scope. It does not disclose the approved coating schedule, inspection limits, acceptance criteria or measured savings. A series award is a reason to watch how the programme progresses. It does not provide a specification that another owner can copy into a tender.

In an earlier fleet announcement, Knutsen described newbuild contracts for seven vessels and named Hanwha Ocean. That release describes a contracting milestone. Use Jotun’s November statement when referring to the nine vessels in the coating announcement. The supplier and owner releases concern different decisions and should be kept as separate records.

Make the application record traceable by hull area

Before coating work begins, ask the yard and coating supplier to agree on a zone drawing, the approved system and the inspection plan. Ask who will sign off each stage and how repairs will be recorded. For each zone, useful records include the approved surface preparation, ambient conditions during application, the batch and layer applied, dry-film thickness readings against the approved schedule, and the disposition of any repair. This is a checklist for a tender, with acceptance limits set by each project’s approved documents.

Test the record with a simple handover question. If a patch is repaired during construction, can the owner identify where it was, the material used, the inspection after repair and who accepted it? A single shipwide pass sheet is unlikely to answer that question. The same zone reference should carry through to the final handover pack and later hull surveys.

Keep the in-service performance baseline separate

A yard inspection records the condition at handover. Assessing operating performance requires a defined baseline, comparable operating points and a record of events that change hull condition. Agree in advance which speed, power and operating data will be available, how changes in draft, weather and sea state will be handled, and when prolonged lay-up, cleaning or damage will split the comparison into separate periods. A change in fuel use alone cannot identify how much of the difference came from the coating.

The public scope of ISO 19030-2 is a useful example of how narrowly a method can be defined. It addresses changes in hull and propeller performance for the same ship over time and describes its applicability to commercial displacement ships driven by conventional fixed-pitch propellers. Check applicability and the agreed method for the ship in question before writing any performance requirement. Jotun’s announcement does not identify a project test under this standard.

Ask for different evidence at each decision

Evidence to request when comparing bids, accepting yard work and reviewing performance.
DecisionEvidence to request
Compare tendersThe coating schedule by hull zone, the proposed inspection plan and responsibilities for resolving deviations.
Accept the yard’s workSigned area-specific checks, batch and repair records, and the agreed disposition of outstanding items.
Review performance in serviceBaseline and measurement method, comparable operating data, and records of cleaning, damage and prolonged inactivity.

The tender can require that all three sets of records use the same zone references and identify the responsible parties. That makes later comparisons useful when a superintendent needs to distinguish a local application defect from a vessel-wide change in operating conditions. For related coverage, see MOS Coating’s industry insights.